Table 2. | Study characteristics according to methodology |
| Study |
Year of publication |
Study design | Patient | Orthodontic procedure and anchorage | Intervention method | Intervention location | Control | ||
|---|---|---|---|---|---|---|---|---|---|
| No. |
Gender (M/F) |
Age (years) | |||||||
| Salman et al. [7] | 2014 | Split-mouth RCT | 15 | 5/10 |
21.7 (17 to 28) |
Maxillary canine retraction |
KaVo laser device (using special hand piece with fiberoptic delivery system) Er:YAG laser (parameters for bone ablation and another type of hand piece in non-contact mode with constant water spray irrigation) |
Between the canine and the second premolar, buccally 4 circular holes were made (2 to 3 mm apart, 1.5 mm in diameter, about 3 mm depth) | Maxillary canine retraction without intervention |
| Mahmoudzadeh et al. [8] | 2020 | Split-mouth RCT | 12 | 9/3 |
18.91 (SD 3.87) |
Maxillary canine retraction done with MBT brackets with 0.022 x 0.028-inch slots and 0.016 x 0.022-inch SS wire with 9-mm NiTi coil springs delivering 150 g force.
First molar used as anchorage |
Er,Cr:YSGG laser (3.5 W, 30 Hz, H' mode, 40% air/80% water) with MZ5 tip (500 µm) | Vertical buccal incisions, 1 mm below the alveolar crest and parallel to the mesial and distal root surfaces, extended to the mucogingival junction (2 to 3 mm deep) | Maxillary canine retraction without intervention |
| Alfawal et al. [9] | 2018 | Split-mouth RCT | 17 | 5/12 |
17.47 (SD 3.3) |
Maxillary canine retraction done with MBT brackets (0.022-inch slots), 0.019 x 0.025-inch SS wire, and NiTi closed-coil springs delivering 150 g force.
First molar used as anchorage |
Er:YAG laser with R14C handpiece and 1.3 x 8 mm tip at 100 mJ, 10 Hz, 2 W; then 200 mJ, 12 Hz, 3 W for cortical perforations, under water–air spray cooling in non-contact mode (tip 1 to 2 mm from tissue) | Five buccal gingival perforations between upper canine and second premolar, each 1.3 mm wide, 1.5 to 2 mm apart, and 3 mm deep | Maxillary canine retraction without intervention |
| Jaber et al. [15] | 2022 | Split-mouth RCT | 18 | 7/11 |
16.9 (SD 2.5) |
Maxillary canine retraction with MBT brackets (0.022-inch), 0.019 x 0.025-inch SS wire, and elastic chains from first molar to canine brackets delivering 150 g force.
Titanium mini-screws used as anchorage |
Er:YAG laser: gingival application with 2062 handpiece (200 mJ, 10 Hz), then cortical bone perforations with 2060 handpiece (200 mJ, 15 Hz) directed through pilot beam on prepared gingival sites | Eight buccal gingival perforations (1 mm width, 3 mm depth): four at first premolar extraction sites and four around the evaluated canine | Maxillary canine retraction without intervention |
| Toodehzaeim et al. [16] | 2024 | Split-mouth RCT | 12 | 5/7 | 15 to 30 |
Maxillary canine retraction done with MBT brackets with 0.022 x 0.028-inch slots and 0.019 x 0.025-inch SS wire with NiTi coil springs delivering 150 g force.
First molar used as anchorage |
Er:YAG laser at 2 W, 100 mJ, 10 Hz, MSP mode with air/water spray; then 3 W, 200 mJ, 12 Hz, QSP mode for cortical bone perforation | Buccally, midway between canine and second premolar, three perforations were made with 2 to 3 mm cortical bone incision | Maxillary canine retraction without intervention |
| Bakr et al. [17] | 2023 | Split-mouth RCT | 14 | 2/12 |
20.4 (SD 2.5) |
Maxillary canine retraction done with MBT brackets (0.022-inch), 0.017 x 0.025 SS wire and 9-mm closed-coil springs from canine to first molar delivering 150 g force.
Titanium mini-screws used as anchorage |
Er,Cr:YSGG laser (2780 nm, MZ8 tip 800 µm x 6 mm) at 2.5 W, 40 Hz, 62.5 mJ, H-mode, 20 air:40 water; for bone, 4.5 W, 40 Hz, 112.5 mJ, H-mode, same air/water ratio | Using a custom guide, the first hole was made 6 mm above the bracket slot, with three mesial and three distal holes (2 mm apart) parallel to the canine root, each 3 mm deep into medullary bone to enhance bleeding | Maxillary canine retraction without intervention |
| Chauhan et al. [18] | 2022 | Split-mouth RCT | 15 | - | 15 to 30 | Maxillary canine retraction with ROTH PEA 0.018-inch, rigid SS arch wire (0.016 x 0.022-inch), NiTi closed coil springs of 9 mm length with force of 150 g for both sides |
Er:YAG laser (2,940 nm) 3 W (QSP mode, Energy = 200 mJ, water and air sprays and pulse frequency = 15 Hz) |
Interproximal area between right maxillary canine and first premolar, four holes diameter 1.5 mm, distal to the canine | Maxillary canine retraction without intervention |
RCT = randomized controlled trial; M = male; F = female; MBT brackets = McLaughlin, Bennett, Trevisi brackets; N/A = not applicable. |