Study | Year of publication | Study type | Patient number |
Patient age (years) |
Gender | Implant sample | Dental implant systems | Implant alloy or coating material |
Follow-up period (years) |
---|---|---|---|---|---|---|---|---|---|
Gadzo et al. [24] | 2023 | RCT | 43 | 67.3 (SD 11) |
21 females, 22 males |
69 |
Astra Tech Implant System™ EV (Dentsply Sirona); Straumann ITI® (Straumann AG) |
TiO-blasting; SLA |
10 |
Ioannidis et al. [25] | 2019 |
Prospective RCT |
64 | > 18 |
38 females, 26 males |
57 |
Astra Tech Implant System™ EV (Dentsply Sirona); Straumann® (Straumann AG) |
TiO-blasting; SLA |
5 |
Koller et al. [26] | 2020 |
Prospective RCT |
22 | > 18 |
9 females, 13 males |
31 |
Ziterion® Vario T (Ziterion GmbH) |
Sandblasted titanium; sandblasted zirconia |
5 |
Raes et al. [27] | 2018 | RCT | 15 | 46 to 72 |
4 females, 11 males |
83 |
Brånemark MK III® (Nobel Biocare AB) |
Anodic oxidation; turned implant |
5 |
Donati et al. [28] | 2018 | RCT | 25 | 57.6 (SD 10) | 25 females | 64 |
Astra Tech Implant System™ EV (Dentsply Sirona) |
Turned implant; TiO-blasting |
20 |
RCT = randomized controlled trials. |