Study | Dental implant systems |
Implant alloy or coating material |
Clinical parameters immediately after implant loading (mm) | Clinical parameters after 5 years or more after implant loading (mm) |
The difference between clinical criteria (mm) |
||||||
---|---|---|---|---|---|---|---|---|---|---|---|
BOP | PD | MBL | BOP | PD | MBL | BOP | PD | MBL | |||
Mean (SD) | Mean (SD) | Mean (SD) | Mean (SD) | Mean (SD) | Mean (SD) | Mean (SD) | Mean (SD) | Mean (SD) | |||
Gadzo et al. [24] |
Astra Tech Implant System™ EV (Dentsply Sirona); Straumann ITI® (Straumann AG) |
TiO-blasting; SLA |
0.2 (0.2); 0.2 (0.2) |
3.1 (0.5); 2.7 (1) |
-0.1 (0.4); 0.04 (0.54) |
0.1 (0.1); 0.1 ( 0.1) |
2.8 (0.5); 2.9 (0.7) |
-0.1 (0.47)*; -0.78 (0.96)* |
-0.2 (0.3); -0.1 (0.2) |
-0.3 (0.6); 0.2 (1.1) |
0.01 (0.41)*; -0.82 (1.26)* |
Ioannidis et al. [25] |
Astra Tech Implant System™ EV (Dentsply Sirona); Straumann® (Straumann AG) |
TiO-blasting; SLA |
0.24 (0.22); 0.21 (0.18) |
3.13 (0.51); 2.83 (0.88) |
0.29 (0.44)*; 0.22 (0.44)* |
0.26 (0.2); 0.3 (0.26) |
3.19 (0.39); 3.33 (0.57) |
0.13 (0.54); 0.34 (0.45) |
0.03 (0.33); 0.1 (0.3) |
0.06 (0.65)*; 0.48 (0.92)* |
-0.18 (0.47)*; 0.1 (0.35)* |
Koller et al. [26] |
Ziterion® Vario T (Ziterion GmbH) |
Sandblasted titanium; sandblasted zirconia |
- | - |
0.92 (0.72); 1.51 (0.68) |
16.43 (6.16)%*; 12.6 (7.66)%* |
- |
1.38 (0.81); 1.17 (0.73) |
- | - | - |
Raes et al. [27] |
Brånemark MK III® (Nobel Biocare AB) |
Anodic oxidation; turned implant |
- | - |
-1.85 (0.8); -1.82 (0.62) |
3.78 (2.28)*; 2.76 (2.52)* |
4.19 (2.61); 3.09 (1.01) |
- | - | - |
-1.65 (1.65); -1.00 (0.9) |
Donati et al. [28] |
Astra Tech Implant System™ EV (Dentsply Sirona) |
Turned implant; TiO-blasting |
- | - | - | - |
3.7 (1.03); 4. (1.3) |
-0.41 (1.25); -0.83 (1.59) |
- | - |
-0.41 (1.25); -0.83 (1.59) |
*Statistically significant values (P < 0.05).
|