« Prev |
2020 Oct-Dec; Vol 11, No 4:e1 |
Next » |
e1 |
The Reliability and Influence of Body Position on Acoustic Pharyngometry and Rhinometry Outcomes J Oral Maxillofac Res 2020;11(4):e1 doi:10.5037/jomr.2020.11401 Abstract | HTML | PDF | XML |
The Reliability and Influence of Body Position on Acoustic Pharyngometry and Rhinometry Outcomes
1Section of Orthodontics, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark.
Corresponding Author:
Section of Orthodontics, Department of Odontology
Faculty of Health and Medical Sciences, University of Copenhagen
20 Nørre Alle, DK-2200 Copenhagen
Denmark
Phone: 0045 35 32 66 70
E-mail: alson@sund.ku.dk
ABSTRACT
Objectives: The aim of this cross sectional study was to analyze the method error and reliability in acoustic pharyngometry and rhinometry and to analyze the difference between standing and sitting position in acoustic pharyngometry and rhinometry.
Material and Methods: The sample comprised 38 healthy subjects (11 men and 27 women) as part of a control group in another study. The subjects underwent repeated measures of acoustic pharyngometry and rhinometry in standing and sitting position. Upper airway dimensions in terms of volume, minimum cross-sectional areas (MCA) and distances were evaluated using the Eccovision® Acoustic Pharyngometer and Rhinometer. Method error and reliability were analyzed using paired t-test, Dahlberg’s formula and the Houston reliability coefficient, and differences between body positions were analyzed using paired t-test.
Results: There was no systematic error in the repeated measures except for the distance to MCA in the left nostril in sitting position (P = 0.041). The method error for the pharyngometry ranged between 0.001 to 0.164 cm/cm2/cm3, and the reliability was 0.99. The method error for rhinometry ranged between 0.001 to 0.37 cm/cm2/cm3 and the reliability between 0.99 to 1. Difference between standing and sitting position was found only in the pharyngeal airway in terms of volume (P = 0.025) and mean area (P = 0.009) with smaller airway in sitting position.
Conclusions: The results indicate that acoustic pharyngometry and rhinometry are reliable methods to perform repeated measures of the upper airway dimensions especially in the standing mirror position. It may be essential to perform the measures with the patient positioned in the same body position each time.
J Oral Maxillofac Res 2020;11(4):e1
doi: 10.5037/jomr.2020.11401
Accepted for publication: 19 October 2020
Keywords: acoustics; healthy volunteers; observer variation; pharynx; posture; reproducibility of results.
To cite this article: The Reliability and Influence of Body Position on Acoustic Pharyngometry and Rhinometry Outcomes J Oral Maxillofac Res 2020;11(4):e1 URL: http://www.ejomr.org/JOMR/archives/2020/4/e1/v11n4e1ht.htm |
Received: 13 August 2020 | Accepted: 19 October 2020 | Published: 31 December 2020
Copyright: © The Author(s). Published by JOMR under CC BY-NC-ND 3.0 licence, 2020.